Search results for "Cardiac Catheterization"
showing 10 items of 69 documents
12‐Month outcomes of transcatheter tricuspid valve repair with the PASCAL system for severe tricuspid regurgitation
2021
Objectives We investigated the durability of tricuspid regurgitation (TR) reduction and the clinical outcomes through 12 months after transcatheter tricuspid valve repair (TTVr) with the PASCAL Transcatheter Valve Repair System. Background TTVr has rapidly developed and demonstrated favorable acute outcomes, but longer follow-up data are needed. Methods Overall, 30 patients (age 77 ± 6 years; 57% female) received PASCAL implantation from September 2017 to May 2019 and completed a clinical follow-up at 12 months. Results The TR etiology was functional in 25 patients (83%), degenerative in three (10%), and mixed in two (7%). All patients had TR severe or greater (massive or torrential in 80%)…
Circulatory response to volume expansion and transjugular intrahepatic portosystemic shunt in refractory ascites: Relationship with diastolic dysfunc…
2015
Abstract Background Cirrhotic cardiomyopathy may lead to heart failure in stressful circumstances, such as after transjugular intrahepatic portosystemic shunt (TIPS) placement. Aim To examine whether acute volume expansion predicts haemodynamic changes after TIPS and elicits signs of impending heart failure. Methods We prospectively evaluated refractory ascites patients (group A) and compensated cirrhotics (group B), who underwent echocardiography, NT-proBNP measurement, and heart catheterization before and after volume load; group A repeated measurements after TIPS. Results 15 patients in group A (80% male; 54 ± 12.4 years) and 8 in group B (100% male; 56 ± 6.2 years) were enrolled. Echoca…
Centre procedural volume and adverse in‐hospital outcomes in patients undergoing percutaneous transvenous edge‐to‐edge mitral valve repair usingMitra…
2021
AIMS The number of transcatheter mitral valve repair (TMVr) procedures has increased substantially during the last years. A better understanding of the relationship between hospital volume of transcatheter transvenous mitral valve repairs using MitraClip® and patient outcomes may provide information for future policy decisions to improve patient management. METHODS AND RESULTS We analysed patient characteristics and in-hospital outcomes for all TMVr procedures using MitraClip® performed in Germany from 2011 to 2017. Hospitals were stratified according to centre volumes and patients were compared for baseline characteristics and adverse in-hospital events. Overall, 24 709 inpatients were tre…
Feasibility of a MPR-based 3DTEE guidance protocol for transcatheter direct mitral valve annuloplasty.
2020
Objectives Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. Methods …
Randomized comparison between the invasive and conservative strategies in comorbid elderly patients with non-ST elevation myocardial infarction.
2016
Abstract Background Comorbid elderly patients with non-ST-elevation myocardial infarction (non-STEMI) are underrepresented in randomized trials and undergo fewer cardiac catheterizations according to registries. Our aim was to compare the conservative and invasive strategies in these patients. Methods Randomized multicenter study, including 106 patients (January 2012–March 2014) with non-STEMI, over 70 years and with comorbidities defined by at least two of the following: peripheral artery disease, cerebral vascular disease, dementia, chronic pulmonary disease, chronic renal failure or anemia. Patients were randomized to invasive (routine coronary angiogram, n = 52) or conservative (coronar…
A New Technical Approach For Retrograde Administration of Cardioplegic Solutions
1989
Myocardial protection via the coronary sinus is now currently used by several groups. Although it has generally provided satisfactory results, some of its problems are still not completely resolved. We present a new technique of cardioplegia delivery through the coronary sinus with a Pezzer catheter inserted into it and secured in place by a purse string suture. We believe that this method is safer and more reliable than others.
Increased Cancer Incidence Following up to 15 Years after Cardiac Catheterization in Infants under One Year between 1980 and 1998—A Single Center Obs…
2020
Objective: To evaluate the incidence of cancer within the first 15 years of life in children who underwent cardiac catheterization under the age of one year. Methods: In this retrospective, single center study, 2770 infants (7.8% with trisomy 21) were studied. All infants underwent cardiac catheterization under one year of age between January 1980 and December 1998. Newly diagnosed cancer in the first 15 years of life was assessed through record linkage to the German Childhood Cancer Registry (GCCR). Cancer risk in study patients was compared to the GCCR population of children less than 15 years. Patients with trisomy 21 were compared to the Danish Cytogenic Register for trisomy 21. Effecti…
Transgastric imaging-The key to successful periprocedural TEE guiding for edge-to-edge repair of the tricuspid valve.
2021
Intraprocedural transesophageal echocardiography (TEE) guidance plays an essential role in transcatheter repair therapy of the tricuspid valve (TV). So far, several different imaging concepts are in use. We propose an imaging protocol that fully addresses the morphological complexity of the TV and further offers efficacious workarounds for the frequently occurring restrictions of TV imaging in edge-to-edge repair of the TV. As a tertiary referral center with a large experience of more than 250 cases of transcatheter edge-to-edge repair (TEER) of the TV performed at the Heart Valve Center in Mainz/Germany, we have constantly adapted our peri-interventional echocardiographic approach to accom…
Percutaneous closure of left atrial appendage to prevent embolic events in high-risk patients with chronic atrial fibrillation
2009
Background: Percutaneous closure of the left atrial appendage (LAA) is a novel alternative for the treatment of patients with atrial fibrillation (AF) and with a high risk of stroke who are not eligible for long-term anticoagulation therapy. The aim of this study was to asses the safety, feasibility, and long-term efficacy of this procedure. Methods: From July 2004 to June 2007, 20 patients (13 male, mean age 69 ± 8 years) with non–valvular AF (NV-AF) underwent LAA percutaneous closure using the PLAATO™ system, implanted through a transeptal access. All patients had contraindications to anticoagulant therapy and were at high risk for cardioembolic stroke (mean CHADS2 score 3 ± 1.2). A trans…
From Clinical Imaging to Patient-Specific Computational Model: Rapid Adaptation of the Living Heart Human Model to a Case of Aortic Stenosis
2021
Aortic stenosis (AS) is the most common acquired heart valve disease in the developed world. Traditional methods of grading AS have relied on the measurement of aortic valve area and transvalvular pressure gradient. Recent research has highlighted the existence of AS variants that do not meet classic criteria for severe AS such as low-flow, low-gradient AS. With the development of sophisticated multi-scale computational models, investigation into the left ventricular (LV) biomechanics of AS offers new insights into the pathophysiology that may guide treatment decisions surrounding AS. Building upon our prior study entailing LV-aortic coupling where AS conditions were applied to the idealize…